Works
After the raw water into the condenser, put the tube around the
high-temperature pure steam distilled water condensation, cooling,
its been warm. Raw water pre-heater tower through the column tube,
the temperature gradually raised to the boiling point close to an
effective temperature. This increased temperature to the boiling
point of raw materials required for the thermal energy (steam heat)
minimum.
Machine works as follows: (The following data is listed in the
heating steam 0.3Mpa operating conditions of the situation).
Raw water from the nozzle device into distilled water through the
flow meter, cylinder diaphragm valves, into the condenser, the
condenser by high-temperature distilled water from the tower, as
well as the end of the second tower of steam preheating, raw
material flowing out from the condenser The temperature is 80~
110between, I tower heat exchanger, the steam heated by the stripes
preheating, the temperature gradually raised, and then from the
pre-Division I enter the tower, within the column tube when the
temperature exceeds 130 ℃, I entered the water tower of the
high-temperature materials by the Department from the nozzle into a
steam heating (tube between the tower column), which showed thin
film along the inner surface of the tube-like shed, and quickly
evaporate. Heated steam in the heat release after I tower through
the trap from the condensing water nozzle b Department discharged.
The above-mentioned part of the raw water has been evaporated, the
steam generated through the spiral separation plate to remove the
water droplets entrained in the steam and hot after the original,
importcontrol tower, the tower as a heat source of heat Ⅱ, the
other part does not evaporate The raw water, through the throttling
orifice, through the throttling expansion enteredtower tube tower,
was re-concentrated and evaporation. Subsequent to the tower are
the same principles and so on. Finally out from the tower of high
purity, qualified high-temperature distilled water and the end of
the tower all the introduction of secondary steam condenser is raw
water and cooling water as cooling, condensation. Of distilled
water outlet temperature controlled at 92~ 99 ℃, out of distilled
water from the condenser mounted on the quality of the resistivity
of distilled water pipe-line monitoring and control instrument, if
the distilled water to the required quality requirements, that is,
j from the nozzle output, the other hand, K discharged from the
nozzle, containing in the distillation process of gathering all the
impurities have been condensed water from the pipe mouth g
discharged. Condenser within the non-condensable gas from the
nozzle h discharge.