Home Company Info Product List Contact Details
Homeproduct Directory

:TRA-type 10000 with the cam rotor pump

:TRA-type 10000 with the cam rotor pump
company Yong's Pharmaceutical Equipment Co., Ltd
Categories Latex Rubber
Update2011-03-23
Original RegionChina
:TRA-type 10000 with the cam rotor pump

TRA-type 10000 with the cam rotor pump
Overview:
TRA-type cam rotor pump is never on the pump in the traditional re-design of TR-type transformation, its performance is more optimized, more compact structure, beautiful and efficient.

Structure:
Use of coupling the whole assembly, so that smaller size (length can be shortened 100-250mm), reduction of area, compact structure, outsourcing of stainless steel, mirror polished, beautiful appearance, high grade, to avoid the shedding of the original Paste Paint .

Performance Optimization:
Assembled with coupling as a whole to reduce the elastic coupling power consumption, noise and wear and tear replacement and improve work efficiency, the rotor is the result of extensive research, the use of 3D CAD design is completed, get the highest efficiency, the smallest internal sliding and longer life.
I. Introduction-purpose pumps
10000 also known as colloid with pump pump, rotor pump, clover pump, pump shoes, etc. are widely used in food, beverage, chemical, pharmaceutical and other industries. Because the shape of the pump rotor is more specific and accurate high expectations, so few successful production of domestic manufacturers. A large number of users can only purchase imported equipment. To change this undesirable situation, I plant organized technical personnel to research, compiled with the C-curve design process and enter the rotor machining center for precision machining, thus ensuring the key components of the pump of high-precision requirements and stringent compliance requirements. The following performance characteristics of the pump profile is as follows:
(-) 10000 with the pump works:
10000 synchronized with the pump on the reverse rotation of the rotor 2 (teeth 2-4) during rotation generated at the entrance of suction (vacuum degree), thereby conveying the material to be inhaled. Two rotor rotor chamber will be separated into several small space, according to a b c d in the order of operation. To the position of a running, only I room filled with media; to the position of b,, B room closed off part of the media; to the position of C,, A room has also closed the media; to the position of d,, A Room B Room andRoom interlinked, media Jibei transported to discharge port. So on ad infinitum, medium (materials) Jibei out endless conveyor.


(B) 10000 with the pump characteristics:
1. And centrifugal pump (pump milk) in comparison: centrifugal pump because of its simple structure, low cost and has been widely used. With 10000 compared with the main pumps have the following differences:
a) 10000 is a positive displacement pump with the pump delivery flow can be more accurate control can also be easily made into variable pump. The centrifugal pump output flow is unable to control the resistance increases with the decline: 10000 with the pump have a stronger self-priming capability and centrifugal pumps in operation must be filled before the
Full of liquid.
b) 10000 with the pump speed is very low, generally between 200rpm to 600rpm, was transported material has been steadily output and its components will not be damaged. The high speed centrifugal pump has been subject to powerful impact transportation of materials, as well as the role of centrifugal force, so a mixture of centrifugal pumps in the transportation of material often produces the phenomenon of different ingredients, so that the finished product quality,the 10000 pump is used to solve this problem the best choice, so it is especially suitable for transfer or mixture of materials containing solid particles.
c) 10000 with the pumps can be used to transport a high viscosity material, so also known as colloidal pump. The centrifugal pump there is no such feature.
d) 10000 with the pump output pressure can be easily made into a higher species, such as 1.5MPa, suitable for long distance or high-resistance quantitative transmission.
e) million, compared with the production of pump sophisticated, high cost, which is also its greatest disadvantage when compared with the centrifugal pump.
2, with the screw pump (thick Pump) comparison: both belong to the same displacement pump, so its performance is nearly similar - can be a smooth transfer of high viscosity material, there is a higher delivery pressure. But the biggest disadvantage of a screw pump determines its health requirements in a non-applicability of the occasion - due to the non-streamlined surface as well as the screw chamber a large number of resident determines that it can not become a health-stage pump, parietal PTFE or rubber material shift transmission loss is more likely to be material and cause pollution. The 10000 pump with the flow line structure due to the rotor and the rotor chamber basically no dead spots and non-metallic parts, so strictly speaking, the food and b